Vista de página 0
APC
Modular Panel Products
T
he APC Modular Panel Product Surge Protective Devices (SPD)
are designed to provide protection at the service entrance, branch
panels or other critical locations for today’s electrical equipment.
Compliant with UL 1449 2nd Edition requirements
dated February 9, 2007.
PMF3S-A
PMF3DS-A
PMP3S-A
PMP3DS-A
PMG3S-A
PMG3DS-A
PML3S-A
PML3DS-A
PMF4S-A
PMF4DS-A
PMP4S-A
PMP4DS-A
PMG4S-A
PMG4DS-A
PML4S-A
PML4DS-A
PMH4DSLM-A
Installation and Operation Manual
Surge Protective Devices (SPD)
1-800-800-4272 | www
.apc.com
Retain for future use
The APC SurgeArrest® Modular Panel Mount Products have
replaceable phase modules with integrated LED monitoring, a
display panel with surge counter and LED status indicators, an
audible alarm, and a NEMA 3R/12 Enclosure. Modular Panel
Products are available with 120kA and 160kA maximum surge
current per phase ratings.
PML-4Y-DC-DL-A
Vista de página 0
1 2 3 4 5 6 ... 19 20

Resumo do Conteúdo

Página 1 - Modular Panel Products

APC Modular Panel ProductsThe APC Modular Panel Product Surge Protective Devices (SPD) are designed to provide protection at the service entrance, bra

Página 2

SYSTEM GROUNDINGCAUTIONSYSTEM GROUNDING· SPD must be installed on solidly grounded power systems. · Verify that the service entrance equipment is b

Página 3 - IMPORTANT!

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH· Apply appropriate personal protective equipment (PPE) and follow safe electrical work pr

Página 4 - CONTENTS

Note: Prior to mounting the SPD, verify that the device has the same voltage rating as the power distribution system in which it is installed by compa

Página 5 - INTRODUCTION

WIRING DIAGRAMS WITHOUT INTEGRAL DISCONNECTFigure 3: Single-Phase, 3-Wire, GroundedChasis GroundChasis Ground ØC ØA NCustomer Connections 120 kA - 240

Página 6

8220-0014-06Customer Connections 320 kA - 480 kAØCØA NCustomer Connections 120 kA - 240 kA ØC ØA BØ NWIRING DIAGRAMS WITH INTEGRAL DISCONNECTChasis Gr

Página 7

The SPD display panel shows the status of the modules withOn wye and split phase configuration SPD modules (see Figure 7), if the left green LED is no

Página 8

Push the alarm enable/disable button to enable or disable the alarm. If the green alarm LED is lit the alarm is enabled. If the green alarm LED is not

Página 9 - NDERSIZED WIRING

The contacts are designed for a Maximum voltage of 24 VDC and a maximum current of 2 A. Higher energy applications may require additional relay implem

Página 10

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH· Apply appropriate personal protective equipment (PPE) and follow safe electrical work pr

Página 11

STARTPossible diagnosticdisplay board failure.Replace diagnosticdisplay panel. Is powerbeing suppliedto theSPD?Green phase LED(s)not lit. And, noRe

Página 12

DANGERHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH· Apply appropriate personal protective equipment (PPE) and follow safe electrical work pract

Página 13 - Grounded Wye Installation

Entire contents copyright 2008 by American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is p

Página 14 - Chasis Ground

CAUTIONLOSS OF SURGE PROTECTION· During installation into an electrical system, SPD’s must not be energized until the electrical system is compl

Página 15

CONTENTSINTRODUCTION ...UNPACKING AND PRELIMINARY INSPECTION ...

Página 16 - Note: Three phase model shown

INTRODUCTION Thank you for choosing the APC SurgeArrest® PM3 or PM4 Series Surge Protection Device. The APC modular Surge Protection Device (SPD) is

Página 17 - Terminals

Proper installation is imperative to maximize the APC Modular Panel SPD’seffectiveness and performance. The installer should follow the steps outline

Página 18

The identification nameplate (see Figure 1) is located on the inside of the door/cover.Figure 1: SPD Nameplate ExampleIDENTIFICATION NAMEPLATESAFETY L

Página 19

Prior to mounting the SPD, verify that the device has the same voltage rating as the power distribution system in which it is installed by comparing t

Página 20 - Entire contents copyright 2

The integral switch is a second mechanical means for qualified maintenance personnel to isolate the entire surge suppressor to service the device’s co