Página 1 - Operation Manual

Operation ManualSmart-UPS® UPS750/1000/1500/2200/3000 VA Tower120/230 VAC

Página 2 - Contents

7Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower ConfigurationUPS SettingsStart-up SettingsConfigure these settings at initial start-up, using

Página 3

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 8Low Transfer Point120 V: 106 Vac• 97 Vac• 100 Vac• 103 Vac• 106 VacSet the transfer point lowe

Página 4

9Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Main Outlet Group and the Switched Outlet GroupOverviewThe Main Outlet Group and the Switched

Página 5 - Rear panels

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 10Network Management Card Settings These settings are available only on units that have a Netwo

Página 6 - Installation

11Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Emergency Power OffEPO OverviewThe Emergency Power Off (EPO) option is a safety feature that

Página 7 - Operation

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 12TroubleshootingProblem and Possible Cause SolutionThe UPS will not turn on or there is no out

Página 8 - Display Interface

13Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower The replace battery indicator is illuminatedThe battery has a weak charge. Allow the battery

Página 9 - Advanced menus

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 14Service and SupportServiceIf the unit requires service, do not return it to the dealer. Follo

Página 10 - Configuration

15Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Transport the unit1. Shut down and disconnect all connected equipment.2. Disconnect the unit

Página 11

Smart-UPS Factory WarrantyLIMITED WARRANTYAmerican Power Conversion (APC) warrants its Smart-UPS (Products) to be free from defects in materials and w

Página 12 - Overview

ContentsSmart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower iOverview ... 1P

Página 13 - UNTIME REMAINING setting

Harmonized StandardsEN62040-1-1, EN62040-2, EN60950-1, IEC60950-1, EN55022, EN55024, IEC61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-11Applicable Counci

Página 14 - Emergency Power Off

06/2009990-3534-001 © 2009 APC by Schneider Electric. APC, the APC logo are owned by Schneider Electric Industries S.A.S., American Power Conversion C

Página 15 - Troubleshooting

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower iiEmergency Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 16

1Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower OverviewProduct DescriptionThe APC® by Schneider Electric Smart-UPS® 750-3000 VA 120/230 Vac T

Página 17 - Service and Support

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 2Rear panelsUSB port750 VA 120 Vac 750 VA 230 VacSerial portGround screwSmart slotCircuit

Página 18 - Transport the unit

3Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower SpecificationsOperating ConditionsThis unit is intended for indoor use only. Select a location

Página 19 - Smart-UPS Factory Warranty

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 4OperationConnect Equipment to the UPSNote: The UPS will charge to 90% capacity in the first th

Página 20 - Date of product declaration

5Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower Display InterfaceOverviewUsing the display interfaceUse UP and DOWN to scroll through the main

Página 21 - 06/2009990-3534-001

Smart-UPS 750/1000/1500/2200/3000 VA 120/230 Vac Tower 6Advanced menusThe Advanced menus provide additional options for the UPS and are available only