APC IN ROW RD ACRD101 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Software de gestão de rede APC IN ROW RD ACRD101. APC IN ROW RD ACRD101 User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 76
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Users Guide
InRow RD 100-Series
InRow RD 200-Series
ACRD100
, ACRD101
ACRD200, ACRD201
DATA CENTER SOLUTIONS
For More Information:
(866) 787-3271
Sales@PTSdcs.com
Vista de página 0
1 2 3 4 5 6 ... 75 76

Resumo do Conteúdo

Página 1 - User’s Guide

User’s GuideInRow RD 100-SeriesInRow RD 200-SeriesACRD100, ACRD101ACRD200, ACRD201DATA CENTER SOLUTIONSFor More Information:(866) 787-3271Sales@PTSdcs

Página 2

InRow RD 100-Series and InRow RD 200-Series User’s Guide3• A Read-Only User has the following restricted access:– Access through the Web interface on

Página 3 - Contents

4InRow RD 100-Series and InRow RD 200-Series User’s GuideStatus and Link RX/TX LEDsStatus LEDThis LED indicates the status of the InRow RD. Link-RX/TX

Página 4

InRow RD 100-Series and InRow RD 200-Series User’s Guide5Watchdog FeaturesOverviewTo detect internal problems and recover from unanticipated inputs, t

Página 5

6InRow RD 100-Series and InRow RD 200-Series User’s GuideControl ConsoleHow To Log OnOverviewYou can use either a local (serial) connection, or a remo

Página 6

InRow RD 100-Series and InRow RD 200-Series User’s Guide7Local access to the control consoleFor local access, use a computer that connects to the InRo

Página 7

8InRow RD 100-Series and InRow RD 200-Series User’s Guide• The Up Time field reports how long the InRow RD has been running since it was last turned o

Página 8 - Introduction

InRow RD 100-Series and InRow RD 200-Series User’s Guide9Control Console MenusOverviewThe control console provides options to monitor and configure th

Página 9 - Internal Management Features

10InRow RD 100-Series and InRow RD 200-Series User’s GuideNetwork menuTo perform these tasks, use the options of the Network menu:• Configure the TCP

Página 10

InRow RD 100-Series and InRow RD 200-Series User’s Guide11Web InterfaceIntroductionOverviewThe Web interface provides options to manage the InRow RD.S

Página 11 - Status and Link RX/TX LEDs

12InRow RD 100-Series and InRow RD 200-Series User’s GuideURL address formatsType the DNS name or IP address of the InRow RD in the URL address field

Página 13 - Control Console

InRow RD 100-Series and InRow RD 200-Series User’s Guide13Home PageOverviewOn the Overview page of the Home tab, displayed when you log on to the Web

Página 14 - Main Screen

14InRow RD 100-Series and InRow RD 200-Series User’s GuideHow to Use the Tabs, Menus, and LinksTabsIn addition to the tab for the Home page, the follo

Página 15 - Main screen status fields

InRow RD 100-Series and InRow RD 200-Series User’s Guide15Group and Unit ConfigurationViewing and Configuring Group SettingsOverview pageThe Overview

Página 16 - Control Console Menus

16InRow RD 100-Series and InRow RD 200-Series User’s Guide• Fan Speed Preference — The preferred fan speed for normal operation of the cooling unit. S

Página 17 - System menu

InRow RD 100-Series and InRow RD 200-Series User’s Guide17The value InRow RD should always display in the unit-type field. You can group InRow RD 100-

Página 18 - Web Interface

18InRow RD 100-Series and InRow RD 200-Series User’s GuideStatus > Detailed Status page• Input State—The current state of the input contact. If the

Página 19 - URL format examples

InRow RD 100-Series and InRow RD 200-Series User’s Guide19Thresholds pageSensor Values. View the temperature values reported by these sensors:• Rack I

Página 20 - Home Page

20InRow RD 100-Series and InRow RD 200-Series User’s GuideLogsUse the Event and Data LogsEvent log Path: Logs > Events > optionsYou can view, fi

Página 21 - Quick Links

InRow RD 100-Series and InRow RD 200-Series User’s Guide21Note: Events are processed through the filter using OR logic. • Events that you do not selec

Página 22 - Group and Unit Configuration

22InRow RD 100-Series and InRow RD 200-Series User’s GuideTo filter the log by date or time (Logs > Data > log): To display the entire data log,

Página 23 - Units page

ContentsInRow RD 100-Series and InRow RD 200-Series User’s GuideiIntroduction ... 1P

Página 24 - Status > Overview page

InRow RD 100-Series and InRow RD 200-Series User’s Guide23How to use FTP or SCP to retrieve log filesAn Administrator or Device User can use FTP or SC

Página 25 - Service Intervals page

24InRow RD 100-Series and InRow RD 200-Series User’s GuideTo use SCP to retrieve the files. To use SCP to retrieve the event.txt file, use the followi

Página 26 - Thresholds page

InRow RD 100-Series and InRow RD 200-Series User’s Guide25Administration: SecurityLocal UsersSetting user access Path: Administration > Security &g

Página 27 - Use the Event and Data Logs

26InRow RD 100-Series and InRow RD 200-Series User’s GuideSelect one of the following:• Local Authentication Only: RADIUS is disabled. Local authentic

Página 28 - Data log

InRow RD 100-Series and InRow RD 200-Series User’s Guide27Configuring the RADIUS ServerSummary of the configuration procedureYou must configure your R

Página 29 - To delete the data log:

28InRow RD 100-Series and InRow RD 200-Series User’s GuideInactivity Timeout Path: Administration > Security > Auto Log OffUse this option to co

Página 30

InRow RD 100-Series and InRow RD 200-Series User’s Guide29Administration: Network FeaturesTCP/IP and Communication SettingsTCP/IP settingsPath: Admini

Página 31

30InRow RD 100-Series and InRow RD 200-Series User’s GuideDHCP response optionsEach valid DHCP response contains options that provide the TCP/IP setti

Página 32 - Administration: Security

InRow RD 100-Series and InRow RD 200-Series User’s Guide31Vendor Specific Information (option 43). The InRow RD uses this option in a DHCP response to

Página 33

32InRow RD 100-Series and InRow RD 200-Series User’s GuideOther options. The InRow RD also uses these options within a valid DHCP response. All of the

Página 34 - Configuring the RADIUS Server

InRow RD 100-Series and InRow RD 200-Series User’s GuideiiControl Console Menus . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 35 - Inactivity Timeout

InRow RD 100-Series and InRow RD 200-Series User’s Guide33• Select naming to define the host name and domain name of the InRow RD:– Host Name: After

Página 36 - TCP/IP settings

34InRow RD 100-Series and InRow RD 200-Series User’s GuideWebPath: Administration > Network > Web > optionsOption Descriptionaccess To activa

Página 37 - DHCP response options

InRow RD 100-Series and InRow RD 200-Series User’s Guide35ssl certificateAdd, replace, or remove a security certificate.Status:• Not installed: A cert

Página 38

36InRow RD 100-Series and InRow RD 200-Series User’s GuideConsole Path: Administration > Network > Console > optionsOption Descriptionaccess

Página 39 - Port Speed

InRow RD 100-Series and InRow RD 200-Series User’s Guide37Note: To use SSH, you must have an SSH client installed. Most Linux and other UNIX® platform

Página 40

38InRow RD 100-Series and InRow RD 200-Series User’s GuideSNMPv3Path: Administration > Network > SNMPv3 > optionsFor SNMP GETs, SETs, and tra

Página 41 - Option Description

InRow RD 100-Series and InRow RD 200-Series User’s Guide39user profilesBy default, lists the settings of four user profiles, configured with the user

Página 42

40InRow RD 100-Series and InRow RD 200-Series User’s GuideFTP Server Path: Administration > Network > FTP ServerThe FTP server settings enable (

Página 43 - Console

InRow RD 100-Series and InRow RD 200-Series User’s Guide41Administration: Notification and LoggingEvent Actions Path: Administration > Notification

Página 44

42InRow RD 100-Series and InRow RD 200-Series User’s GuideConfiguring by event. To define event actions for an individual event:1. Select the Administ

Página 45

InRow RD 100-Series and InRow RD 200-Series User’s GuideiiiLogs ...20Use

Página 46

InRow RD 100-Series and InRow RD 200-Series User’s Guide43Active, Automatic, Direct NotificationE-mail notificationOverview of setup. Use the Simple M

Página 47 - FTP Server

44InRow RD 100-Series and InRow RD 200-Series User’s GuideE-mail recipients. Path: Administration > Notification > E-mail > recipientsIdentif

Página 48 - Event Actions

InRow RD 100-Series and InRow RD 200-Series User’s Guide45SNMP trapsTrap Receivers. Path: Administration > Notification > SNMP Traps > trap r

Página 49

46InRow RD 100-Series and InRow RD 200-Series User’s GuideSyslogPath: Logs > Syslog > optionsThe InRow RD can send messages to up to four Syslog

Página 50 - E-mail notification

InRow RD 100-Series and InRow RD 200-Series User’s Guide47Syslog Test and Format example. Path: Logs > Syslog > testSend a test message to the S

Página 51 - E-mail recipients

48InRow RD 100-Series and InRow RD 200-Series User’s GuideAdministration: General OptionsIdentification Path: Administration > General > Identif

Página 52 - SNMP Trap Test

InRow RD 100-Series and InRow RD 200-Series User’s Guide49When customizing Daylight Saving Time (DST):• If the local DST always starts or ends on the

Página 53 - Syslog Settings

50InRow RD 100-Series and InRow RD 200-Series User’s GuideReset the Interface Path: Administration > General > Reset/RebootSerial ModbusPath: Ad

Página 54 - Queries (SNMP GETs)

InRow RD 100-Series and InRow RD 200-Series User’s Guide51To reconfigure any of the following, click the link name in the Display column:• Display: Th

Página 55 - Set the Date and Time

52InRow RD 100-Series and InRow RD 200-Series User’s GuideAPC Device IP Configuration WizardCapabilities, Requirements, and InstallationHow to use the

Página 56 - Temperature Units

InRow RD 100-Series and InRow RD 200-Series User’s GuideivAdministration: Notification and Logging... 41Event Actions . . . . . . . .

Página 57 - Configuring Links

InRow RD 100-Series and InRow RD 200-Series User’s Guide53Use the WizardNote: Most software firewalls must be temporarily disabled for the Wizard to d

Página 58 - About the InRow RD

54InRow RD 100-Series and InRow RD 200-Series User’s GuideConfigure or reconfigure the TCP/IP settings locally1. Contact your network administrator to

Página 59 - Installation

InRow RD 100-Series and InRow RD 200-Series User’s Guide55How to Export Configuration SettingsRetrieving and Exporting the .ini FileSummary of the pro

Página 60 - Use the Wizard

56InRow RD 100-Series and InRow RD 200-Series User’s GuideCustomizing. You must customize the file before you export it.1. Use a text editor to custom

Página 61

InRow RD 100-Series and InRow RD 200-Series User’s Guide57The Upload Event and Error MessagesThe event and its error messagesThe following event occur

Página 62 - Detailed procedures

58InRow RD 100-Series and InRow RD 200-Series User’s GuideRelated TopicsOn Windows operating systems, instead of transferring .ini files, you can use

Página 63

InRow RD 100-Series and InRow RD 200-Series User’s Guide59File TransfersUpgrading FirmwareBenefits of upgrading firmwareWhen you upgrade the firmware

Página 64 - Messages in config.ini

60InRow RD 100-Series and InRow RD 200-Series User’s GuideTo extract the firmware files:1. Run the tool.2. At the prompts, click Next>, and then sp

Página 65 - Related Topics

InRow RD 100-Series and InRow RD 200-Series User’s Guide613. Type open and the InRow RD’s IP address, and press ENTER. If the port setting for the FTP

Página 66 - File Transfers

62InRow RD 100-Series and InRow RD 200-Series User’s GuideUse XMODEM to upgrade one InRow RDTo upgrade the firmware for one InRow RD that is not on th

Página 67 - C:\apc>ftp

InRow RD 100-Series and InRow RD 200-Series User’s GuidevHow to Export Configuration Settings...55Retrieving and Exporting the .

Página 68

InRow RD 100-Series and InRow RD 200-Series User’s Guide63Last Transfer Result codesVerify the version numbers of installed firmware.Use the Web inter

Página 69

64InRow RD 100-Series and InRow RD 200-Series User’s GuideIndexAAbout optionsfor information about the Management Card 51Accessenabling or disabling m

Página 70 - Last Transfer Result codes

InRow RD 100-Series and InRow RD 200-Series User’s Guide65SSH 36reverse lookup 21SSL cipher suites 34Telnet 36versions of SSH 36Error messagesfrom ove

Página 71

66InRow RD 100-Series and InRow RD 200-Series User’s GuideMMain screen of control consoleinformation fields displayed 7status fields displayed 8MenusC

Página 72

InRow RD 100-Series and InRow RD 200-Series User’s Guide67Syslogidentifying the Syslog server and port 46mapping event severity to Syslog priorities 4

Página 74

9/2009990-3632APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of the following ways:

Página 75

InRow RD 100-Series and InRow RD 200-Series User’s Guide1IntroductionProduct DescriptionFeaturesThe APC by Schneider Electric InRow RD 100-series and

Página 76 - 9/2009990-3632

2InRow RD 100-Series and InRow RD 200-Series User’s GuideNetwork management featuresThese applications and utilities work with the InRow RD.• APC Inf

Comentários a estes Manuais

Sem comentários