APC SYPM2KU Manual de Instalação

Consulte online ou descarregue Manual de Instalação para Adaptadores e conversores de corrente APC SYPM2KU. APC Symmetra RM3 Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Installation Manual

990-1031, Revision 1 8/00APC Symmetra RMInstallation ManualEnglish

Página 2 - Life Support Policy

6How To Contact APCInternethttp://www.apc.com/supportNorth AmericaPhone 1.800.800.4272Fax 1.401.788.2743Email [email protected] America, South Ame

Página 3 - Table of Contents

7Product OverviewFront View Component IdentificationFigure 2: Front View of the Symmetra RMPower Module(s) : The Symmetra RM can support between on

Página 4 - List of Figures

8Rear View Component IdentificationFigure 3: Rear View of the Symmetra RM (200/208 Vac / L1-L2-G version shown)System Fan : The system fan can be r

Página 5 - Electrical Safety

9Input Voltage Selection Switch : Set this switch to the appropriate setting, either 200/208 (L1-L2-G) or220/230/240 (L1-N-G) before powering up the

Página 6 - Battery Safety

10System Block DiagramFigure 4: System Block DiagramMIM RIMCOM CardAccessoryCardsPowerView DisplayDB9COMPortBatteryMonitorBusExternal BatteryPowerInp

Página 7 - Radio Frequency Interference

11CHAPTER 3: INSTALLATIONUnpackingAPC has taken care to design robust packaging for your product. However, accidents and damage may occurduring ship

Página 8

12Determine the Location of the Symmetra RM in the Rack1. Select a location for the Symmetra RM in your NetShelter enclosure or other 19-inch (46.5 c

Página 9 - About Your UPS

13Install the UPS into the Rack1. With two people supporting the Symmetra RM,one on each side, carefully align the cleats on thesides of the unit wit

Página 10 - How To Contact APC

141. Make sure the main circuit breaker , located on the rearpanel, is in the OFF position.2. Select the appropriate wire size and connectors, acco

Página 11 - Product Overview

15Use one of the following cable types to connect the Symmetra RM to the EPO switch:CL2 Class 2 cable for general use.CL2P Plenum cable for use in duc

Página 12

990-1031, Revision 1 8/00Limited WarrantyAmerican Power Conversion (APC) warrants its products to be free from defects in materials and workmanshipfo

Página 13

16Install battery modules just prior to running the Symmetra RM. The battery modulesdischarge slowly when loaded prematurely and can be damaged perma

Página 14 - System Block Diagram

17APPENDIX A: ELECTRICAL WIRING CHECKLISTComplete this checklist to ensure that the Symmetra RM has been wired properly.Ensure that all switches (sy

Página 15 - Installing the Symmetra RM

185. Record input voltages below and compare the values with the measured voltages from step 1. If the twomeasurements are significantly different, c

Página 16 - YMMETRA RM OPERATION MANUAL

990-1031, Revision 1 8/00Table of ContentsChapter 1: Safety Information...1Conventions Use

Página 17 - 220/230/240

990-1031, Revision 1 8/00List of FiguresFigure 1: Symmetra RM...

Página 18

1CHAPTER 1: SAFETY INFORMATIONThis Safety section contains important instructions that should be followed during installation and maintenanceof the A

Página 19

2• Use one hand, whenever possible, to connect or disconnect signal cables to avoid a possible shock fromtouching two surfaces with different electric

Página 20

3Recycling of BatteriesSee your dealer or Replacing Modules in the SYMMETRA RM OPERATION MANUAL, for information onreplacement battery kits and batter

Página 22

5CHAPTER 2: BASICSAbout Your UPSThe Symmetra RM is a high-performance, uninterruptible power system in a “power array” configuration,designed to powe