Apc Silcon DP300E Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Ferramentas Apc Silcon DP300E Series. APC Silcon DP300E Series User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 38
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
1User Guide Silcon DP300E Series 480V 400-500kVA
7OA0004 US rev. 02
Copyright © 1999 APC Denmark A/S
Due to continuous product development information
given in this manual is subject to change without notice.
7OA0004 US rev. 02
Silcon DP300E Series
480V 400–500kVA
User Guide
Vista de página 0
1 2 3 4 5 6 ... 37 38

Resumo do Conteúdo

Página 1 - User Guide

1User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Copyright © 1999 APC Denmark A/SDue to continuous product development informationgiv

Página 2 - SAVE THESE INSTRUCTIONS

10 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02WARNING!If the UPS is out of service formore than 48 hours theconnected batteries

Página 3 - Table of Contents:

11User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0210. Turn all input switches (Q001) to position “0“.On systems with dual utility, tu

Página 4 - Introduction

12 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02DP300EDP300EQ010aQ001aQ002aQ004Q010bQ001b Q002bUtility 1Q003Service bypass switchH

Página 5 - CAUTION!

13User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02The following can be carried out on any UPS14. Press on the keyboard15. Press or

Página 6

14 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02DP300EDP300EQ010aQ001aQ002aQ004Q010bQ001b Q002bUtility 1Q003Service bypass switchH

Página 7

15User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Operation3.0 OperationThe display is used to show parameters, alarms/messages, and

Página 8

16 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.0 Programming Parameters4.1 GeneralSome operating parameters can be programmed d

Página 9

17User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.2.2 Keys used for programming4.2.3 Programming example - sw

Página 10 - 7OA0004 US rev. 02

18 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.3 Programming of system configuration parametersThe system configuration paramet

Página 11

19User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.3.2 Programming example – change charge voltage to 446V*Act

Página 12

2 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02IMPORTANT SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONSThis manual contains important

Página 13

20 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 024.4 Programming of battery monitorAction Display shows1. Press and simultaneous

Página 14

21User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming Parameters4.5 Parallel programming/operationProgramming parameters for

Página 15 - Operation

22 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Programming ParametersAction Display shows1. Press and simultaneously to openfor

Página 16 - Programming Parameters

23User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Parallel operation alarms.General.If alarms concerning the parallel operation commu

Página 17

24 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Measurements98.01.1610.22,13Mains 1 voltage480 480 480 VacBattery current+ 20 AdcM

Página 18 - Programming parameters

25User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.0 Alarms - What To Do6.1 GeneralAlarms are indicated by the red LED (above

Página 19

26 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.4 The events loggerThe events logger is a memory stack, in which the last

Página 20

27User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Alarms6.6 Possible alarmsPossible alarm1. Peak current limiter active2. Bypass powe

Página 21

28 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02AlarmsPossible alarmDescription Action20. High temp. isolationtransformer21. High

Página 22

29User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02AlarmsPossible alarm Description Action39. System is locked in oper.mode40 RAM1 mem

Página 23

3User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Table of Contents:1.0 Introduction1.1 General1.2 The display unit2.0 Stop, Start &am

Página 24 - Measurements

30 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 027.0 Remote Display7.1 Remote Display OperationThe remote display is an inactive un

Página 25 - 6.0 Alarms - What To Do

31User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Remote DisplayPossible alarm DescriptionBattery MCB is off Battery MCCB not closed

Página 26 - 6.4 The events logger

32 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 028.0 Preventive Maintenance8.1 GeneralThe maintenance of the Silcon DP300E UPS syst

Página 27 - 6.6 Possible alarms

33User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02WARNING!The UPS must at least be inoperation for min. 16 hours in a3 month period t

Página 28

34 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Preventive Maintenance8.5 Battery monitor testThe battery monitor has two main pu

Página 29

35User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Preventive Maintenance8.5.4 Operation of the battery monitorThe operation of the ba

Página 30 - Remote Display

36 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02NOTE:When using economy modethere is NO power factorcorrection on the input orregu

Página 31

37User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0210.0 System Specifications10.1 Technical dataInput Voltage 3 x 480VVoltage toleranc

Página 32 - Preventive Maintenance

38 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 0211.0 How to Contact APCHow to Contact APCFor more information call:Tel: (800) 800-

Página 33

4 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Introduction1.0 Introduction1.1 GeneralCongratulations on your choice of Silcon DP3

Página 34

5User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Stop, Start & Operating the External Service Bypass Panel2.0 Stop – Start and Op

Página 35

6 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 021. Prepare the system by opening the front door(s).2. Continue with the next point

Página 36 - Economy Operation

7User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Start up of system now completed.2.5 Start (from complete power down)2.5.1 Starting

Página 37 - System Specifications

8 User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Single UtilityDual Utility2.6 Operating the external service bypass switch, single

Página 38 - How to Contact APC

9User Guide Silcon DP300E Series 480V 400-500kVA7OA0004 US rev. 02Action1. Turn the input switch (Q001) to position “1”.If dual utility is present, tu

Comentários a estes Manuais

Sem comentários