Página 1 - Operation

OperationSY160K160HPDUM160H-BSYCFXR9Symmetra® PX UPS,Power Distribution Unit, andXR Battery Enclosure160 kW 400 V

Página 2

Overview: User Interface4 Symmetra PX 160 kW 400 V Operation 990-3015-001Display interfaceOverview screens. When the system is running, the display w

Página 3 - About this Manual

Overview: User Interface990-3015-001 Symmetra PX 160 kW 400 V Operation 5Menu treeCaution: Do not make changes to any screens that are not described

Página 5 - Contents

990-3015-001 Symmetra PX 160 kW 400 V Operation 7OperationOperation ModesIn an installation without a maintenance bypass panel, the UPS has four diff

Página 6

8 Symmetra PX 160 kW 400 V Operation 990-3015-001Operation ProceduresNote: If the system does not contain a PDU-XR, the Q1, Q2, Q3, and Q5 switches a

Página 7

Operation: Operation Procedures990-3015-001 Symmetra PX 160 kW 400 V Operation 9Set the upstream mains power to the OFF or LOCKED OUT position. If t

Página 8

Operation: Operation Procedures10 Symmetra PX 160 kW 400 V Operation 990-3015-001Set the Q2 switch on the PDU-XR to the OFF position. Turn the UPS

Página 9 - Overview

Operation: Operation Procedures990-3015-001 Symmetra PX 160 kW 400 V Operation 11How to return to normal operation Set the DC DISCONNECT switch on a

Página 10 - Display interface

Operation: Operation Procedures12 Symmetra PX 160 kW 400 V Operation 990-3015-001Press ESC to go back to the UPS Control screen and select UPS into

Página 11 - Menu tree

990-3015-001 Symmetra PX 160 kW 400 V Operation 13ConfigurationSystem Settings How to change the date and time Use the UP and DOWN arrow keys to navi

Página 14 - Operation Procedures

990-3015-001 Symmetra PX 160 kW 400 V Operation 15MaintenanceParts ReplacementHow to determine if you need a replacement partTo determine if you need

Página 15

Maintenance: Parts Replacement16 Symmetra PX 160 kW 400 V Operation 990-3015-001Replacement parts Warning: Only trained persons familiar with the con

Página 16 -  Press  Press

Maintenance: Parts Replacement990-3015-001 Symmetra PX 160 kW 400 V Operation 17How to remove a power moduleTurn the locking latch down until the ar

Página 17

Maintenance: Parts Replacement18 Symmetra PX 160 kW 400 V Operation 990-3015-001How to replace a power management peripheralLoosen the two Phillips s

Página 18 - How to view the Log screen

Maintenance: Parts Replacement990-3015-001 Symmetra PX 160 kW 400 V Operation 19How to replace a battery module.Holding the handle, gently lift the

Página 20

990-3015-001 Symmetra PX 160 kW 400 V Operation 21TroubleshootingUPS AlarmsThis section lists all of the alarm and status messages that might be displ

Página 21 - Maintenance

Troubleshooting: UPS Alarms22 Symmetra PX 160 kW 400 V Operation 990-3015-001External DC Disconnect Switch OpenThe external DC DISCONNECT switch tripp

Página 22 - Replacement parts

Troubleshooting: UPS Alarms990-3015-001 Symmetra PX 160 kW 400 V Operation 23Low Battery The UPS is in battery operation and the battery charge is low

Página 23 - How to install a power module

990-3015-001 Symmetra PX 160 kW 400 V Operation iAbout this ManualThis manual is for the 160 kW Symmetra® PX UPS, Power Distribution Unit (PDU-XR), an

Página 24

Troubleshooting: UPS Alarms24 Symmetra PX 160 kW 400 V Operation 990-3015-001Redundant Intelligence Module FaultThe redundant intelligence module has

Página 25

990-3015-001 Symmetra PX 160 kW 400 V Operation 25Modular Distribution fault listThe display interface will identify the number of the power distribut

Página 26

26 Symmetra PX 160 kW 400 V Operation 990-3015-001PDU fault listDisplay Message Meaning Corrective ActionMaintenance Bypass AlarmThe system is in main

Página 30

04/2007990-3015-001*990-3015-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of

Página 32 - PDU fault list

Contents990-3015-001 Symmetra PX 160 kW 400 V Operation iiiSafety...1Over

Página 33

iv Symmetra PX 160 kW 400 V OperationMaintenance...15Parts Replacement . . . . . . . .

Página 34

990-3015-001 Symmetra PX 160 kW 400 V Operation 1SafetyWarning: All safety instructions in the Safety sheet (990-2984) should be read, understood, an

Página 36 - *990-3015-001*

990-3015-001 Symmetra PX 160 kW 400 V Operation 3OverviewUser InterfaceInterface areaNLOAD POWERED LEDWhen green, power to the load is on. When flas

Comentários a estes Manuais

Sem comentários