Cooling Solutions
APC
Power, Cooling and Environmental Monitoring
D
./Cooling Solutions;Air Conditioners/14715
Index1.Support and Supplies//Physical Sup port Structure//Accessories
AMERICAN POWER CONVERSION
The InRow Chilled Water product design closely couples the cooling with the IT heat
load. This design prevents hot air recirculation, while improving cooling predictability
and allowing for a pay as you grow environment. Available with or without humidity
control, these products are designed to meet the diverse requirements for medium- to
large-sized data centers. Data center operators looking to improve efficiency or
deploy high-density servers will benefit from the modular design of the InRow Chilled
Water products. The intelligent controls of the InRow Chilled Water products actively
adjust fan speed and chilled water flow to match the IT heat load to maximize
efficiency and address the dynamic demands of today's IT environments.
INROW CHILLED WATER (UP TO 70 KW) PR29551V2-219629.eps
The InRow Chilled Water product design closely couples the cooling with the IT heat
load. This design prevents hot air recirculation, while improving cooling
predictability and allowing for a pay as you grow environment. Available with and
without humidity control, these products are designed to meet the diverse
requirements for medium- to large-sized data centers. Data center operators looking
to improve efficiency or deploy high-density servers will benefit from the modular
design of the InRow Chilled Water products. The intelligent controls of the InRow
Chilled Water products actively adjust fan speed and chilled water flow to match the
IT heat load to maximize efficiency and address the dynamic demands of today's
IT environments.
INROW DIRECT EXPANSION (UP TO 43 KW) PR29552V2-219623.eps
The InRow Direct Expansion product design closely couples the cooling with the IT
heat load. This design prevents hot air recirculation, while improving cooling
predictability and allowing for a pay as you grow environment. Available in
self-contained, fluid cooled, and air-cooled configurations with or without humidity
control, these products meet the diverse requirements for closets, server rooms, and
data centers. IT operators looking to improve efficiency or deploy higher-density
equipment will benefit from the modular design of the InRow Direct Expansion
products. The intelligent controls of the InRow Direct Expansion products actively
adjust fan speed and refrigerant flow to match the IT heat load to maximize
efficiency and address the dynamic demands of today's IT environments.
Row Cooling Systems
Anixter No. Vendor No. Description
353880 ACRC100 InRow RC 300 mm chilled water, 100-120 V
50/60 Hz, NEMA L5-20
397479 ACRC103 InRow RC 300 mm chilled water, 200-240 V
50/60 Hz, IEC 309-16
397480 ACRC500 InRow RC 600 mm chilled water, 200-240 V
50/60 Hz
397482 ACRC501 InRow RC 600 mm chilled water, 460-480 V
60 Hz
354859 ACRP500 InRow RP 600 mm chilled water, 200-240 V
50/60 Hz
354861 ACRP501 InRow RP 600 mm chilled water, 460-480 V
60 Hz
Anixter No. Vendor No. Description
354856 ACSC100 InRow SC air-cooled self-contained 200-240 V
60 Hz
397484 RACSC101 InRow SC System, (one) InRow SC, (one)
NetShelter SX Rack 600 mm, and
rear containment
397491 RACSC112 InRow SC System, (one) InRow SC, (one)
NetShelter SX Rack 600 mm, with front and
rear containment
397492 RACSC201 InRow SC System, (two) InRow SC units, (one)
NetShelter SX rack 600 mm, and
rear containment
397495 ACRD500 InRow RD, 600 mm, air-cooled, 200-240 V,
50/60 Hz
397496 ACRD100 InRow RD, 300 mm, air-cooled, 200-230 V,
60 Hz
397497 ACRD200 InRow RD, 300 mm, fluid-cooled, 200-230 V,
60 Hz
397499 ACRD501 InRow RD, 600 mm, air-cooled, 460-480 V,
60 Hz
354858 ACRP100 InRow RP, 600 mm, air-cooled 200-240 V
50/60 Hz
354857 ACRP101 InRow RP, 600 mm, air-cooled 460-480 V 60 Hz