APC RAID Subsystem SCSI-SATA II Informações Técnicas Página 128

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 127
Advanced Functions
5-10
5.2 Multiple ID solutions
5.2.1 Overview
The multiple ID mechanism provides host transparent controller failover/failback solution. That is, no particular software
or driver is required to be installed at the host side. Howerver, a fiber switch is required. Through the connection of fiber
switch, the fiber host chanel ports can provide backup for each other. ‘Fcpa1’ and ‘fcpb1’ can backup each other, so do
‘fcpa2’ and ‘fcpb2’.
For example, if controller A fails, ‘fcpb1’ inherits the target ID of ‘fcpa1’, while ‘fcpb2’ inherits the target ID of ‘fcpa2’. When
the target ID is inherited, the lun-map under the ID is inherited as well. Now, both ‘fcpb1’ and ‘fcpb2’ have two IDs. When
controller A gets failback, ‘fcpb1’ and ‘fcpb2’ disable the inherited ID before ‘fcpa1’ and ‘fcpa2’ are enabled. The
procedure is delicately controlled to achieve seamless failover/failback.
When MTID mode is selected, the topology is set to arbitration loop automatically. The fiber switch ports connected to the
RAID fiber ports should be configured as public loop ports which are often denoted as FL or GL ports. The target loop ID
can be changed manually to avoid conflict with initiator loop ID if a simple fiber hub is used.
At the moment, only FC RAID system supports multiple ID solutions.
As Figure 5-5 shows, the green and the red dotted paths are both active paths. When the green path link fails, the red
dotted path will continue to access all the storage devices without interruption.
To set up the connection, perform these tasks in the RAID GUI:
• Create virtual volumes and specify the preferred controllers
• Specify the storage provisioning method
• Specify the LUN ID and map LUNs to fiber ports
The succeeding Configuration Tasks table shows the details of each configuration task according to the example given in
Figure 5-5.
5
6
7
8
9
0
1
2
3
4
Loop2Loop1
FCP1FCP2FCPa2 FCPa1
(DG0LD0) (DG0LD1)
FCP1FCP2FCPb2 FCPb1
FC Switch
Controller A
(DG1LD0) (DG1LD1)
Controller B
WWPN
WWPN
HBA1HBA0
Server (without
pathguard installed)
Host Group 0
Figure 5-5 MTID environment