APC RAID Subsystem SCSI-SATA II Especificações Página 54

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 94
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 53
Chapter 4: Subsystem Connection and Operation
NOTE:
The subsystem is shipped with one (1) SCSI-to-SCSI daisy chain
cable (IFT-9270UJBODCAB). If you are going to cascade your
subsystems, extra cables must be purchased separately.
To create dual redundant data paths on the host side, it is necessary
to install third-party failover software on the host computer.
4.4 Power On
Once all of the components have been installed in the FALCON II and the
host channels have been connected to the host, the subsystem can be
powered on.
4.4.1 Check List
BEFORE powering on the FALCON II, please check the following:
Memory module: Memory modules have been correctly installed
on the controller boards.
BBU: If used, the BBU has been installed correctly.
Hard drives: Hard drives have been correctly installed in the drive
trays.
Drive trays: ALL the drive trays, whether or not they have a hard
drive, have been installed into the subsystem.
Cable connections: The host ports on the subsystem have been
correctly connected to a host computer.
Power cables: The power cables have been connected to the PSU
modules on the subsystem and plugged into the main power source.
Ambient temperature: All the subsystem components have been
acclimated to the surrounding temperature.
4.4.2 Power On Procedure
When powering on the FALCON II, please follow these steps:
1. Power on the subsystems that are not connected directly to the host
computer, if applied.
If you have daisy chained any FALCON II, power on those
subsystems before powering on the first subsystem that is connected to
your host computer(s).
Power On