APC IN ROW RD ACRD101 Especificações

Consulte online ou descarregue Especificações para Aparelhos de ar condicionado "split system" APC IN ROW RD ACRD101. APC IN ROW RD ACRD101 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Installation

InstallationInRow® RDAir CooledACRD100ACRD101

Página 2 - 동봉된 CD 안에 한국어 매뉴얼이 있습니다

InRow Air Cooled RD Installation2Safety Note: All work should be performed by American Power Conversion (APC®) authorized personnel only. Follow all l

Página 3

3InRow Air Cooled RD InstallationInspecting the EquipmentYour American Power Conversion (APC®) InRowTM RD air conditioner has been tested and inspecte

Página 4

InRow Air Cooled RD Installation4Model IdentificationThe model number can be found on the outside of the shipping crate and on the nameplate located o

Página 5 - Contents

5InRow Air Cooled RD InstallationComponent IdentificationInstall kitNote: Do not discard the install kit.The install kit contains items which may be n

Página 6

InRow Air Cooled RD Installation6Exterior components (front)Removable rear doorAdjustable leveling footSide panel latchDisplay interfaceRemovable

Página 7

7InRow Air Cooled RD InstallationInterior components (front)Electrical control box 1CompressorElectrical control box 2Front air block panelTemper

Página 8

InRow Air Cooled RD Installation8Interior components (rear)Filter/dryerHot gas bypass valvePressure transducer (2) (located behind air block)Liqui

Página 9 - General Information

9InRow Air Cooled RD InstallationElectrical panelLeak detector portBuilding management system (BMS) RS-485 portRemote temperature sensor portContr

Página 10

InRow Air Cooled RD Installation10Top piping and power access locationsBottom piping and power access locationsElectrical inputLiquid lineLow volta

Página 11 - Moving the Equipment

11InRow Air Cooled RD InstallationRefrigeration Piping DiagramNote: Shutoff valves shown nearest to the condensers are not supplied by APC.Note: Route

Página 12 - Model Identification

This manual is available in English on the enclosed CD.Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar.Deze handleiding staat in

Página 13 - Component Identification

InRow Air Cooled RD Installation12Connections OverviewAll connections to and from the equipment can be made through either the top or the bottom of th

Página 14 - Exterior components (front)

13InRow Air Cooled RD InstallationRoom PreparationAir distributionThe equipment distributes air in a back-to-front discharge pattern, removing hot air

Página 15 - Interior components (front)

InRow Air Cooled RD Installation14InstallationRemoving Doors and PanelsDoor removalSide panel removalna2631aWarning: All doors and side panels must b

Página 16 - Interior components (rear)

15InRow Air Cooled RD InstallationPositioning the EquipmentRemove the compressor shipping bracketCaution: Failure to complete the following steps may

Página 17 - Electrical panel

InRow Air Cooled RD Installation16Service accessA minimum 900 mm (36 in) of clear floor space in front of and behind the equipment is recommended for

Página 18

17InRow Air Cooled RD InstallationLeveling the EquipmentNote: The leveling feet at the corners of the equipment provide a stable base if the floor is

Página 19 - Refrigeration Piping Diagram

InRow Air Cooled RD Installation18Joining the Equipment to EnclosuresJoining to SX enclosuresThe equipment comes with four joining brackets (two for t

Página 20 - Connections Overview

19InRow Air Cooled RD InstallationMechanical ConnectionsRefrigeration pipingThe equipment must be connected to a condenser—either a remote outdoor con

Página 21 - Weights and Dimensions

InRow Air Cooled RD Installation20Recommended line sizesEquivalent length m (ft) Line type ACRD100, ACRD101 (OD)15 (50) Discharge line (horizontal) 5/

Página 22

21InRow Air Cooled RD InstallationConnect refrigerant linesBe sure to use only clean, refrigerant-grade (ACR Type L) pipe and follow standard procedur

Página 23 - Positioning the Equipment

American Power Conversion Legal DisclaimerThe information presented in this manual is not warranted by the American Power Conversion Corporation to be

Página 24 - Service access

InRow Air Cooled RD Installation22Condensate pumpThe condensate pumps  are factory-wired and piped internally to the condensate pan. The pumps are ca

Página 25 - Stabilizing the Equipment

23InRow Air Cooled RD InstallationRouting the condensate pump drain line. Route the condensate drain line through the top or the bottom of the equipme

Página 26 - Joining to SX enclosures

InRow Air Cooled RD Installation24Leak sensor (optional)Install one leak sensor (AP9325). To extend the leak sensor length, add up to three additional

Página 27 - Mechanical Connections

25InRow Air Cooled RD InstallationAdding a holding chargeR-410A is a mixed refrigerant. When charging this equipment with mixed refrigerant, only liqu

Página 28 - Equivalent length

InRow Air Cooled RD Installation26Charging TableCondenser Model Selected Ambient TemperatureCondenser Summer Charge (lb)Condenser Flooded Charge (lb)

Página 29 - Flooded receiver

27InRow Air Cooled RD InstallationElectrical ConnectionsThe electrical connections required in the field are:• Controls (display interface, Network M

Página 30 - Condensate pump

InRow Air Cooled RD Installation28User interface connectionsA-Link ports: Pin 1 = High; pin 2 = Low; Pins 3,6 = Perf Power; Pins 4, 5 = GroundNO (no

Página 31

29InRow Air Cooled RD InstallationForm C alarm contacts and shutdown inputSee items 6 through 13 in “User interface connections” on page 28. A relay i

Página 32 - Leak sensor (optional)

InRow Air Cooled RD Installation30Rack temperature sensorThe rack temperature sensor monitors and controls the equipment airflow and ensures an adequa

Página 33 - Adding compressor oil

31InRow Air Cooled RD InstallationA-Link connectionsThe A-Link bus connection allows multiple InRow RD equipment (up to twelve) to communicate with on

Página 35 - Electrical Connections

InRow Air Cooled RD Installation32Building Management System (BMS)The Modbus interface allows each InRow RD to communicate with the BMS. Use a three-w

Página 36 - User interface connections

33InRow Air Cooled RD InstallationNetwork portNetwork portLAN cable (10/100 Base-T)na2679aSwitch/HubInRow RD # 1 InRow RD # 2 Final InRow RD

Página 37

InRow Air Cooled RD Installation34Power ConnectionsWiring configurationsRoute incoming power to the electrical junction box located at the top or bott

Página 38 - Rack temperature sensor

35InRow Air Cooled RD InstallationConnect flooded receiver heaterThe flooded receiver is equipped with a heater to keep the refrigerant warm during ex

Página 39 - A-Link connections

InRow Air Cooled RD Installation36WarrantyOne-Year Factory WarrantyThe limited warranty provided by American Power Conversion (APC®) in this Statement

Página 40

37InRow Air Cooled RD InstallationIN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIATES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT, SPECIAL,

Página 41 - Network port

InRow Air Cooled RD Installation38Warranty ProceduresClaimsTo obtain service under the warranty, contact APC Customer Support (see the back cover of t

Página 42 - Power Connections

Radio Frequency InterferenceChanges or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s

Página 43

03/2008990-3211-001*990-3211-001*APC Worldwide Customer SupportCustomer support for this or any other APC product is available at no charge in any of

Página 44 - Warranty

ContentsInRow Air Cooled RD InstallationiGeneral Information... 1Overview . . . . . . . . . . .

Página 45 - Warranty claims

InRow Air Cooled RD InstallationiiInstallation... 14Removing Doors and Panels . . .

Página 46 - Warranty Procedures

InRow Air Cooled RD InstallationiiiWarranty ...36One-Year Factory Warranty . .

Página 48 - *990-3211-001*

1InRow Air Cooled RD InstallationGeneral InformationOverviewSave these instructionsThis manual contains important instructions that must be followed d

Comentários a estes Manuais